Learn moreAn electric fireplace is the easiest way to give a room a glowing focal point where no chimney exists — and the finish is everything. We install plug-in or hardwired units wall-mounted, set into an existing masonry firebox, or freestanding, and we handle the framing and trim so it sits flush and reads as built-in, not bolted-on. The flame effect becomes a genuine centerpiece on a media wall, a bedroom, or an office. Clean install, clean look, and no venting or gas to worry about.
Of everything Space Fireplace Services installs, the electric fireplace is the simplest appliance and the easiest to put in badly. With no flue to flash and no gas line to leak-test, it gets treated as plug-and-go decor — but a recessed linear unit lives inside finished framing, pulls real amperage through its heater, and telegraphs every out-of-square cut in the wall around it. We bring a new electric install the same finish discipline we'd bring to a gas linear centerpiece: a true recess, the right circuit, and a face that vanishes into the wall. As a design-led local studio, that's the standard in every Metroplex home we work in.
The install starts at the wall and the panel, not the carton the fireplace shipped in. We frame the rough opening squared and plumb to the unit's exact dimensions, hold the manufacturer's intake and exhaust clearances so the heater's thermal cut-off never nuisance-trips, and — for any heater-rated model over roughly 1,500 W — run or coordinate a dedicated 120 V circuit rather than tap a shared outlet that would brown out the room. Plug-in models land on a properly rated receptacle set inside the cavity; hardwired models get a code-compliant whip and junction box. Where electric-fireplace-repair begins only after a working unit fails — framing and power already in place and left alone — this page is about creating that opening, circuit, and mounting from scratch.
We set the full range of new units: wall-mount and recessed linear LED fireboxes as decor heaters; plug-in inserts that retrofit a dead masonry firebox with zero venting; water-vapor 3D-flame fireboxes framed into a feature wall or surround; and outdoor patio-rated units in weatherproof housings for covered porches and three-season rooms. For a homeowner turning a non-working wood firebox into maintenance-free warmth, a plug-in insert is usually the cleanest path — we dimension the firebox, confirm a safe power source reaches it, and trim the unit so it reads intentional instead of improvised.
Since nothing combusts, the safety review on a new install is electrical and clearance-based — and we don't skip it. We size the circuit to the rated heater load, check the intake and outlet clearances against the listing, and confirm a built-in recess isn't trapping heat against combustible studs or choking the unit's own warm-air return. Installed correctly, an electric fireplace is one of the lowest-maintenance heat sources a home can own — and most of the failures a repair tech sees later trace straight back to a clearance or circuit shortcut taken on day one.
What you pay a premium installer for is the part no one sees once the trim is on: the squared cavity, the dedicated home-run circuit, the level set, and the clean reveal where glass meets drywall. We give the cheapest fireplace in the catalog the same care as the most expensive linear unit, because in your finished room there's no such thing as a fireplace that only sort of looks built-in.
We close by commissioning the unit with you — cycling the heater and the flame effect independently, pairing the remote or app, and confirming the circuit holds under load — so the first time it runs isn't a question mark. You're handed a fireplace installed once, correctly, instead of one you'll be calling someone back to fix.
At Space Fireplace Services, a electric fireplace installation is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the electric fireplace installation is built on.
Chimney inspectionA electric fireplace installation isn't a matter of opinion — it's held to published national standards. Space Fireplace builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
UL 2021 is the standard electric fireplaces are evaluated to as fixed and insert heaters, and our installs stay strictly inside the unit's listing and manufacturer instructions. Rough-opening size, intake and exhaust clearances, recess depth: each figure comes from that listing, never from a guess.
Following general NEC continuous-load practice, a heater-rated unit drawing more than 50% of a 15- or 20-amp circuit gets its own dedicated branch circuit, keeping it off shared outlets that would trip or overheat.
Above and beside the unit, mantel, trim, and framing hold to the manufacturer's listed minimum clearances, and any built-in recess is framed so heater air can escape rather than sit trapped against combustible studs.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Space Fireplace verifies them with your local authority having jurisdiction on every job.
We select the unit and confirm the panel can carry a dedicated circuit for it.
The squared recess gets framed to the unit's own dimensions and clearances.
We run the dedicated circuit or set the rated receptacle or whip it calls for.
We set it dead level, tighten the reveal to the finish, then run the heater and flame with you watching.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Squared framing and a true recess, not a stuck-on box
Dedicated, code-compliant circuit sized to the heater load
Turns a dead wood firebox into ventless electric warmth you actually use.
A clean trim reveal and full commissioning on a brand-new unit.
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

Plan on a Level 1 inspection every year — that's the NFPA cadence — with an actual sweep once buildup reaches 1/8" of creosote. For a fireplace you light through the season, that usually lands at once a heating season. Think of it as the upkeep that keeps the centerpiece of the room clean, drawing well, and ready to look its best.
Yes. The inspectors who assess your chimney hold current CSIA (Chimney Safety Institute of America) certifications — you can confirm them in the CSIA member directory at csia.org — and our fireplace installations are handled by NFI specialists. The craft that makes a hearth a showpiece starts with the people standing in front of it.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. A fireplace is the heart of a room; when it's at risk, we treat it that way.
Always. You get a written quote before a single tool comes out, with photos of exactly what we found. Final pricing tracks the chimney's real condition and anything additional the inspection surfaces — no surprises, just a clear picture of what your fireplace needs.
Yes — our annual maintenance membership runs $19.99/month ($240/year) and covers a yearly Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Cancel anytime, no contract. It's the quiet way to keep your hearth looking and working its best year after year.