Chimney Asbestos & Lead Abatement
Clear hidden hazards safely before any hearth update begins.
Learn moreAn open masonry fireplace looks classic but works against you — it radiates a little heat while pulling far more conditioned air up the chimney. Converting it to a sealed, high-efficiency gas or wood insert gives you a cleaner, more contemporary focal point that actually warms the room. We size the appliance to the room and fuel, run a full-length correctly-sized liner with a positive (continuous) connection so it vents and drafts to spec — never a 'slammer' shoved in the opening — and finish it with a built-in surround. A centerpiece that looks current and heats like one.
Thermodynamically, an open masonry fireplace is a net loss — it radiates a little heat into the room while pulling far more conditioned air up the chimney. Converting it to a sealed, high-efficiency insert flips that equation: the same fireplace becomes a genuine heat source that warms the room and stops bleeding your energy. We perform insert conversions to a premium standard — correctly sized appliance, fully lined positive-connection venting, and a finished install that performs exactly as the manufacturer intended.
The reason an open fireplace loses is simple: it's open. Combustion air and a huge volume of room air head up the flue, and most of a wood fire's heat rides along. A high-efficiency gas or wood insert is a sealed firebox that fits into the existing opening, pulling controlled combustion air and radiating and circulating far more of its heat back into the room. EPA-certified inserts reach efficiencies an open fire can't touch — but only if the appliance is installed correctly.
The liner is the make-or-break detail. An insert has to connect to a full-length, correctly sized liner running from the appliance outlet straight to the cap — a positive, continuous connection — so it vents safely and drafts as designed. A 'slammer' install that simply sets the insert in the opening with no connected liner spills combustion products and never performs to spec. We run an insulated stainless liner sized to the insert, make the positive connection, and terminate it properly at the top.
We size and select the appliance to the space and the fuel rather than to whatever's in stock. On gas inserts we make and leak-test the gas connection; on wood, we match the firebox and liner and get the clearances right. Then we finish the surround so the insert looks integrated — a flush, intentional install, not an appliance jammed into a hole. The payoff is comfort and economy at once: lower utility load, real warmth, and on wood inserts the ability to heat through an outage. We handle the permit and inspection and document the venting and any gas test.
At Space Fireplace Services, a open-fireplace to insert conversion is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the open-fireplace to insert conversion is built on.
Chimney inspectionA open-fireplace to insert conversion isn't a matter of opinion — it's held to published national standards. Space Fireplace builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
Venting an insert calls for a full-length, correctly-sized liner with a positive, continuous connection from the appliance collar to the cap; the shortcut known as a slammer install, dropped into an open flue, spills combustion products and fails code.
Sizing follows the specific insert, per NFPA 211 and the manufacturer's listing, so the appliance drafts and performs exactly as designed.
Gas inserts get their connection leak-tested ahead of commissioning, and the result goes into the record.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Space Fireplace verifies them with your local authority having jurisdiction on every job.
Confirm the flue and opening are sound, then size and choose the EPA/high-efficiency insert to match the room and the fuel you want.
Run an insulated stainless liner cut to the insert, connected positively all the way to the cap.
Seat the insert, then make and leak-test the gas connection or confirm wood clearances are right.
Bring the surround flush and clean, confirm the draft pulls, and document the venting and any gas test before we inspect.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
An insert sized to your room and your fuel, rather than to whatever happens to be in stock
A full insulated liner with a positive connection right up to the cap — never a 'slammer'
Gas connections made and leak-tested; wood clearances verified
A flush, built-in surround that's finished, permitted, inspected, and documented
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

Plan on a Level 1 inspection every year — that's the NFPA cadence — with an actual sweep once buildup reaches 1/8" of creosote. For a fireplace you light through the season, that usually lands at once a heating season. Think of it as the upkeep that keeps the centerpiece of the room clean, drawing well, and ready to look its best.
Yes. The inspectors who assess your chimney hold current CSIA (Chimney Safety Institute of America) certifications — you can confirm them in the CSIA member directory at csia.org — and our fireplace installations are handled by NFI specialists. The craft that makes a hearth a showpiece starts with the people standing in front of it.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. A fireplace is the heart of a room; when it's at risk, we treat it that way.
Always. You get a written quote before a single tool comes out, with photos of exactly what we found. Final pricing tracks the chimney's real condition and anything additional the inspection surfaces — no surprises, just a clear picture of what your fireplace needs.
Yes — our annual maintenance membership runs $19.99/month ($240/year) and covers a yearly Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Cancel anytime, no contract. It's the quiet way to keep your hearth looking and working its best year after year.
Last reviewed:
Other services in the Remediation & Remodel category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line